Notice:
Canada is not reachable from US wareshouse, please choose shipping from China.
Upgraded new version , HLW8032 consumption monitoring chipset build in, NO calibration needed,
The measurement error of active power about 0.2%
The measurement error of effective current is 0.5%
The measurement error of effective voltage is 0.5%
Lates Tasmota full version pre flashed
Fully compatible with official Tasmota OTA server
Specification:
- Input voltage:100-240VAC 50/60Hz
- Current:16A(Max)
- Power rating:2200W
- Wireless standard:IEEE802.11b/g/n,2.4GHz
- Housing Color:Whtie
- Operation Temperature:-20℃~+50℃
- Plastic material:ABS+PC
- Fire-protection rating:94-V0
Template:
{"NAME":"Athom Plug V2","GPIO":[0,0,0,3104,0,32,0,0,224,576,0,0,0,0],"FLAG":0,"BASE":18}
GPIOs:
GPIO# Component
GPIO0 None
GPIO1 None
GPIO2 None
GPIO3 CSE7766 Rx
GPIO4 None
GPIO5 Button1
GPIO9 None
GPIO10 None
GPIO12 Relay1
GPIO13 LedLinki
GPIO14 None
GPIO15 None
GPIO16 None
FLAG None
Notice:
HLW8032 occasionally report invalid power measurements for load values below 5W. During this situation it sometimes reports a valid load. By setting SetOption39 to 128 (default) it must read at least 128 invalid power readings before reporting there is no load.
To discard all loads below 6W simply set SetOption39 1 (0 will reset to default on next restart) so it will report no load below 6W.